UV EC3™ IMAGING SYSTEM

Manually controlled system offers operation of the darkroom within easy reach. The light tight darkroom supplies optimum conditions for many imaging applications including Chemiluminescence, fluorescence, bioluminescence and colorimetric imaging.


New Transilluminator design supplies increased performance and efficiency. Product enhancements include a new electronic ballast and cutting-edge construction!

 

EC3 Imaging System

APPLICATIONS

Chemiluminescence

Bioluminescence

Fluorescence

Colorimetric              

          Photo Gallery


Click for Detailed Camera Info

E-MAIL OR CALL FOR PRICES

SYSTEM NAMES CAMERA PRICE
EC3 310 Gel HR Camera (310) $
EC3 410 Chemi HR Camera (410) $
EC3 500 Bio Chemi HR Camera (500) $
EC3 600 Opti Chemi HR Camera (600) $

Adjust the height of the tray to specific, repeatable positions
VisionWorksLS Image and Acquisition Software

The white light plate folds down for illuminating samples

BioLite MultiSpectral Source (see Features below)


MAIN FEATURES

Assortment of CCD cameras including deeply cooled cameras

Application templates

Five-position emission filters

Unique viewing window is UV blocking for quick sample inspection

Easy access fold-down white light plate

Chemi tray fits over the plate for placement of blots

Roll-out tray provides easy access to the UV Transilluminator

Select from several Bench top, patented and awarding winning Transilluminator models (system may be configured with software or optional, check with your UVP representative)

VisionWorksLS Software (system may be configured with software or optional, check with your UVP representative)

Bio Lite ready


TRANSILLUMINATOR

The white light plate folds down for illuminating samples such as Coommassie blue stained or silver stained media

Operate the white light via the software interface

Flip the plate back when not in use

To use the Transilluminator, slide the Transilluminator out on the sliding tray and place samples on the filter surface

To fluoresce samples in the 460-470mm range, place the optional Visi-Blue Plate over the Transilluminator surface


CHEMILUMINESCENT  IMAGING

The Chemi HR, BioChemi HR and OptiChemi HR cameras are cooled CCD cameras recommended for chemiluminescent imaging

Photo shows the BioChemi HR camera

For chemiluminescent applications, the place the Chemi tray on top of the white light plate for placement of blots

Adjust the height of the tray to specific, repeatable positions


BioLite MultiSpectral SOURCE (optional)

For fluorescent plant imaging, place the BioLite tray inside the darkroom

The BioLite supplies a direct source using fiber optic bundles and a closed optical path to tightly control the output spectrum for consistent, repeatable measurements with superior signal to noise ratio

The kit includes an emission and excitation filter set

Link to the BioLite for more information …


VISION WORKS LS IMAGE ACQUISITION & ANALYSIS  SOFTWARE

VisionWorksLS Image Acquisition and Analysis Software can be configured with the system or ordered separately. Check with your local representative for details. This sophisticated package provides comprehensive tools for image capture and analysis of gels, plates and membranes as well as colony counting. Capabilities include:

 

Image acquisition functions for simple image capture and expanded integration options

Apply numerous image enhancements to images

Comprehensive tools for advanced 1D lane densitometry and analysis including area density, molecular weights and colony counting

Support for 21 CFR Part 11 compliance

One-touch automated macros

Define user profiles and preferences

Generate extensive reports and export data

Multiple user network license available

More …



 

SPECIFICATIONS

These systems automatically include the new electronic ballast Transilluminator design! Link to the Bench top or First Light Transilluminator's pages for detailed specifications.

Camera options

Darkroom:

Light tight

Wide access door with UV safety shutoff

Gel viewing window

Sliding tray for Transilluminator

Epi white and UV illumination (365nn and 254nm)

Emission Filters - five positions:

SYBR Green 515-570nm

SYBR Gold 485-655nm

EtBr Red 570-640nm

Software:

VisionWorksLS (system may be configured with software or optional, check with your UVP representative)

Windows 2000 SP4, Windows XP Pro SP2

Transilluminator's:

Select from FirstLight or Benchtop mod

When selecting a Transilluminator, note the new electronic-ballast design Transilluminator models for increased performance and efficiency! Link to the Bench top or First Light Transilluminator's pages for detailed specifications.


UV Index

TOP 

Since 1988 Nation Enterprises, and since 1993 Lapidary Rock Shop has been providing the highest quality products and services to the lapidary market.
1-800-820-3612
E-MAIL: russ@rnbrockshop.com
Copyright©  1998/2010 ®NATION ENTERPRISES
Owned and operated by Russ & Betty Nation
NEW: 08-24-1998
Completely Revised: 11-12-2000
COMPLETE REVISION 05/2007
REV: 10/19/2011