UV BioSpectrum® 2D IMAGING SYSTEM

The BioSpectrum® 2D Imaging System is designed to automate 2D research with one-touch, pre-set or user-defined PC controls for accurate, repeatable imaging and analysis. Achieve fast 100% matching of 2D gels. The fully automated system design with a cooled CCD camera permits multiple applications including 2D, 1D colorimetric and chemiluminescent imaging. The Vision Works 2D software allows 100% matching of 2D spots!
APPLICATIONS
2D protein gels
Visible and fluorescent stains
Single and multiple dyes
2D western blots
Plus 1D, colorimetric, chemiluminescent imaging
| System Names | Camera | PRICE |
| BioSpectrum 800 | Mega Cam Camera (800) | $ |
MAIN FEATURES
Capture superior images with the 8.3 megapixel high resolution, high sensitivity cooled CCD camera
Motorized optics for setting the aperture, zoom and focus
Automated templates for repeat experiments
Light tight darkroom creates optimum imaging conditions
Unique viewing window blocks UV for quick sample inspection
Built-in overhead white light and UV are easily selected from the software interface
Automated control of the five-position emission filter array
Easy access white light illuminator for imaging Coommassie blue or silver stained media
Roll-out tray provides easy access to the UV Transilluminator
Chemi tray fits over the white light plate or UV Transilluminator for placement of blots
Select from several Benchtop, patented and awarding winning Transilluminator models (configured with system or optional)
VisionWorksLS and VisionWorks 2D Software (configured with system or optional)
Accessibility ports built-in for the BioLite (fiber optic multispectral source) as an optional component
In addition to 2D imaging, the system can be used for 1D fluorescent and colorimetric imaging as well as chemiluminescent imaging
TRANSILLUMINATION
White light illuminator for visualizing samples such as Coommassie blue or silver stained media; operate the white light via the software interface
Store the white light plate in the side pocket of the BioSpectrum when not in use
To use the Transilluminator, slide the Transilluminator out on the sliding tray and place samples on the filter surface
To fluoresce samples in the 460-470mm range, place the optional Visi-Blue Plate over the Transilluminator surface
VisionWorks 2D Analysis Software
A guided workflow for straightforward, fast 2D gel analysis.
See VisionWorks 2D tab
Automates research for easy, yet accurate and repeatable results
Controls the motorized zoom lens, epi and transillumination UV and white light, emission filter selection and system power
Allows selection of user-defined templates or default settings
Create macros to quickly execute multiple commands with a click of a button
VisionWorksLS Image Acquisition and Analysis Software
VisionWorksLS Image Acquisition and Analysis Software can be configured with the system or ordered separately. Check with a local representative for details. This sophisticated package provides comprehensive tools for image capture and analysis of gels, plates and membranes as well as colony counting. Capabilities include:
Image acquisition functions for simple image capture and expanded integration options
Apply numerous image enhancements to captured images
Comprehensive tools for advanced 1D lane densitometry and analysis including area density, molecular weights and colony counting
Support for 21 CFR Part 11 compliance
One-touch automated macros
Define user profiles and preferences
Generate extensive reports and export data
Multiple user network license available
More …
SPECIFICATIONS
MegaCam 800 Camera
Darkroom:
Light tight
Wide access door with UV safety shutoff
Gel viewing window
Sliding tray for Transilluminator
Epi white and UV illumination (365nn and 480nm)
Emission Filters - five positions:
SYBR Green 515-570nm
SYBR Gold 485-655nm
EtBr Red 570-640nm
Software:
Interface for automated controls
VisionWorksLS (system may be configured with software or optional, check with a UVP representative)
Windows 2000 SP4, Windows XP Pro SP2
UV Transilluminator's: Select from FirstLight or Benchtop models (system may be configured with software or is optional, check with your UVP representative)
White Light Illuminator (27x27cm) with uniformity at (<5% CV)
Note: FirstLight UV Transilluminator offers extremely uniform UV (<5% CV) which is important for capturing consistent 2D gels and quantitation
Note: VisionWorks 2D Lite or Pro Analysis Software are order separately
OPTIONS
VisionWorks 2D Lite Analysis Software
VisionWorks 2D Pro Analysis Software
BioLite MultiSpectral Source:
Fiber Optic Epi-Illumination
Fiber Optic Transillumination
Transilluminator's: Select from the FirstLight or Benchtop models
Converter Plates:
Visi-Blue Converter Plate
Longwave Converter Plate
Thermal Printer: For archive quality prints in seconds
Gel-Tools:
Gel-Sentry
Step Tablet
Gel-Cutter
Gel-Ruler
Gel-Scooper
Gel-Trays
Computer and monitor
Flat Field Correction (FFC) Plate for Microtiter Plates
BioSpectrum 800 Imaging
System
VisionWorks 2D Lite Analysis Software
VisionWorks 2D Pro Analysis Software
For specifications, refer to the Specifications tab
For optional equipment, refer to the Options tab
Single, multiple user and network licenses available.
A guided workflow for straightforward 2D analysis. Get rapid results from your proteomics data …
VisionWorks 2D Software provides fast results from 2D gels. It offers an economical solution to 2D analysis problems commonly faced by occasional or low throughput users, such as lack of reproducibility, labor intensive protocols and low confidence in results. VisionWorks 2D offers a guided approach for data analysis with the added benefits of speed and objectivity. Get the answers needed using an optimized workflow to quickly find significant proteins for subsequent picking and reporting.
Select from two different VisionWorks 2D packages:
VisionWorks 2D Lite which is limited to six same-stain gel image comparison and
VisionWorks 2D Pro which has no gel image limit.
VisionWorks 2D
Software enables
Simplicity. A simplified workflow guides the user through each analysis step allowing effortless identification of significantly changing proteins.
Objectivity. The guided workflow promotes a consistent analysis approach allowing new or inexperienced users to generate completely objective and reproducible results from their 2D gels.
Speed. Analysis times of less than 10 minutes per image* are typical due to the high streamlined and optimized workflow.
*
Timings based on a single stain experiment with 2 groups, 5 replicates per group
and an image size of 9MB.
Unique VisionWorks 2D Approach
VisionWorks 2D is a unique and validated
approach delivering a major advance for the analysis of single or multiple dyes.
At the foundation of the VisionWorks 2D approach is highly accurate technology
which makes pixel perfect alignment of images achievable. This produces 100%
matching of spots across all images and no missing values in the analyzed data.
The results are statistically robust so users have absolute confidence in the
data generated.
Performing spot detection on perfectly aligned images also means that spot
editing is not required on most experiments, so operator bias can be kept to an
absolute minimum. The result is an incredibly rapid analysis to quickly identify
the significant proteins with negligible effort.
Key Steps in the Workflow
Image
Quality Control
Automatic image quality control assessment and feedback at the start of workflow highlights many potential issues with the image quality before proceeding to the next step
Image
Alignment
Advanced image alignment guides users through the process of adding vector landmarks in a logical manner across the gel image
Automatic alignment process uses the landmarks set by users to fully align all experimental images
Image
Alignment Review
Alignment grid draws attention to problematic areas on the gel image which are most distorted, so users can focus on those areas during the systematic alignment review
Alignment can be manually adjusted if required
Prefiltering and Same Spots Analysis
Unwanted artifacts can be filtered out of the VisionWorks 2D Analysis
Fully automatic VisionWorks 2D Analysis produces data with 100% matching and no missing values which allows robust statistical analysis
Significant spots are ranked for review by fold change and ANOVA (p-value)
Each spot can be assessed using the 2D/3D montage view and expression profiles
Any spot editing is greatly simplified as a single edit on one image and is automatically applied to all images across the entire experiment
Interesting spots are highlighted on the image view as a guide for manual picking
Report Generation
A simple, printable report provides an overview of the spots which warrant further investigation and are selected for picking
Software Flexibility
The VisionWorks 2D software also allows the user to add images to an existing analyzed experiment. This improves the scope of proteomics studies as users are not confined to the original experiment design.
PRICES SUBJECT TO CHANGE WITHOUT NOTICE
MINIMUM ORDER $50.00
![]()

Since 1988 Nation Enterprises,
and since 1993 Lapidary Rock Shop has been providing the highest quality
products and services to the lapidary market.
1-800-820-3612
E-MAIL: russ@rnbrockshop.com
Copyright© 1998/2010 ®NATION ENTERPRISES
Owned and operated by Russ & Betty Nation
NEW: 08-24-1998
Completely Revised: 11-12-2000
COMPLETE REVISION 05/2007
REV: 10/20/2011